Skip to main content
Vibration & Seismic

ShotTrack ViB Devices

Tri-axial vibration and air-overpressure monitors that turn field events into compliance-ready evidence, synced to the cloud.

ViB Pro X device
Dual-range performance

ViB Pro X

Dual-range tri-axial monitoring from 2–40g for blast vibration, structures, and compliance reporting.

  • Selectable 2–40g
  • Real-time visibility
  • Up to 4000 s/s capture
  • Compliance reporting
ViB SaS device
Sound, air & seismicComing soon

ViB SaS

Ground vibration plus optional air-overpressure capture — seismic and acoustic evidence in one deployable unit.

  • Air overpressure (optional mic)
  • Seismic-grade motion
  • Selectable 2–40g
  • Compliance reporting
ViB Max device
Ultra-high-gComing soon

ViB Max

Ultra-high-g tri-axial capture to 1000 g and 64 kHz for extreme near-field work — pit walls, damage studies, and structures metres from the shot.

  • 200g, 500g & 1000g ranges
  • Up to 64,000 s/s
  • Near-field blast work
  • High-shock IP67 enclosure
ViB Nano device
Compact vibration sensor

ViB Nano

Cost-effective tri-axial vibration monitoring in a 70 mm coin-cell-powered unit with Bluetooth control and cloud upload.

  • Selectable 2, 4 & 8g
  • Bluetooth event capture
  • Tri-axial accelerometer
  • Rugged field packaging
Legacy range

Previous-generation instruments

Superseded by our current range — still supported and available on request.

ViB Pro device
Professional monitoringLegacy

ViB Pro

The professional ViB platform for production monitoring — repeatable deployments feeding straight into ShockAI.

  • Selectable g ranges
  • Extended record windows
  • Compliance-ready exports
  • Designed for harsh sites
Compare the range

Specifications side by side

SpecificationViB Pro XDual-range performanceViB SaSSound, air & seismicViB MaxUltra-high-gViB NanoCompact vibration sensor
Accelerometer
  • Ranges: selectable 2, 4, 8, 10, 20 and 40 g
  • Resolution: 20-bit (256,000 LSB/g at 2 g)
  • Bandwidth: DC to 1000 Hz native acceleration
  • Velocity conversion: band-pass 2 to 500 Hz for compliance (PPV) reporting
  • Ranges: selectable 2, 4, 8, 10, 20 and 40 g
  • Resolution: 20-bit (256,000 LSB/g at 2 g)
  • Bandwidth: DC to 1000 Hz native acceleration
  • Velocity conversion: band-pass 2 to 500 Hz for compliance (PPV) reporting
  • Ranges: tri-axial 200, 500 and 1000 g
  • Resolution: 24-bit
  • Bandwidth: 2 Hz to 15 kHz
  • Velocity conversion: band-pass 2 to 500 Hz for near-field damage-criteria analysis
  • Ranges: selectable 2, 4 and 8 g
  • Resolution: 20-bit (256,000 LSB/g at 2 g)
  • Bandwidth: DC to 500 Hz native acceleration
  • Velocity conversion: band-pass 2 to 250 Hz for compliance (PPV) reporting
Sampling and memory
  • Sample rates: selectable 1000, 2000 and 4000 samples per second
  • Record duration: up to 80 s at 1000 s/s, 40 s at 2000 s/s, 20 s at 4000 s/s
  • Onboard memory: up to 100 events
  • Sample rates: selectable 1000, 2000 and 4000 samples per second
  • Record duration: up to 80 s at 1000 s/s, 40 s at 2000 s/s, 20 s at 4000 s/s
  • Onboard memory: up to 100 events
  • Sample rates: selectable 4, 8, 16, 32 and 64 kHz
  • Record duration: To be confirmed
  • Onboard memory: To be confirmed
  • Sample rates: selectable 1000 and 2000 samples per second
  • Record duration: up to 14 s at 1000 s/s, 7 s at 2000 s/s
  • Onboard memory: up to 100 events
Control and timing
  • Control: ShockAI App
  • Triggering: 1% to 80% of selected g range, set per axis
  • Histogram mode: Peak X, Y and Z acceleration every 5 minutes
  • Timing: Onboard GPS with PPS embedded timing, wire-break option underground
  • Control: ShockAI App
  • Triggering: 1% to 80% of selected g range, set per axis
  • Histogram mode: Peak X, Y and Z acceleration every 5 minutes
  • Timing: Onboard GPS with PPS embedded timing, wire-break option underground
  • Control: ShockAI App
  • Triggering: 1% to 80% of selected g range, set per axis
  • Histogram mode: To be confirmed
  • Timing: Onboard GPS with PPS embedded timing, wire-break option underground
  • Control: ShockAI App
  • Triggering: 1% to 80% of selected g range, set per axis
  • Histogram mode: Peak X, Y and Z acceleration every 5 minutes
  • Timing: Time set from last connected device (phone or computer), accurate to one second
Air overpressure
  • Microphone: Not fitted
  • Microphone: sensitivity 12.5 mV/Pa (-38 dB) ±2 dB
  • Frequency response: 2 to 3.15 Hz ±3 dB, 3.15 to 12.5 Hz ±2 dB, 12.5 Hz to 20 kHz ±1 dB
  • Dynamic range: ≥160 dB re 20 µPa (THD < 3%)
  • Microphone: Not fitted
  • Microphone: Not fitted
Power
  • Battery: Rechargeable 4.7 Ah Li-ion, USB-C fast charging
  • Battery: Rechargeable 4.7 Ah Li-ion, USB-C fast charging
  • Battery: Rechargeable 4.7 Ah Li-ion, USB-C fast charging
  • Battery: 620 mAh 3 V coin cell
Physical
  • Dimensions: 133 mm diameter, 36 mm height, 440 g
  • Dimensions: 133 mm diameter, 36 mm height, 440 g
  • Dimensions: 133 mm diameter, 36 mm height, 440 g
  • Dimensions: 68 mm diameter, 28 mm height, 162 g with battery
Data upload
  • Upload: ShockAI App or ShockAI Web-App
  • Upload: ShockAI App or ShockAI Web-App
  • Upload: ShockAI App or ShockAI Web-App
  • Upload: ShockAI App or ShockAI Web-App
  • All ViB instruments sample at a minimum of four times their highest reported frequency (double the Nyquist requirement) for dependable FFT and dominant-frequency analysis.
  • ViB Max specifications are provisional and subject to change prior to release.